FreeAvailable now — free

Tiles / Flooring Calculator

Estimate tile quantities and wastage.

Project & Input Data

%

An editable user-defined allowance — not a universal engineering requirement.

Embedded standards & references

  • Declared area/volume and product dimensions; not structural conformity

Results are engineering aids and require verification by a qualified professional before use on a real project.

Engineering Assumptions

Direct calculation — Bounded geometric measurement and separate supply balance

  • Regular rectangular measurement only; openings cover all surfaces and cannot exceed gross area. Intermediate quantities are not rounded. RICS NRM2(2021) informs measurement boundaries, not a claim to implement every deduction rule.
  • https://www.rics.org/content/dam/ricsglobal/documents/standards/october_2021_nrm_2.pdf
  • Masonry/tiles: repeating module with joint, not a cutting layout; boundaries, bond and patterns need project take-off. No mortar, grout or strength calculation.
  • Paint uses practical product-datasheet coverage per whole coat. Plaster is wet volume only, not mix constituents. Stock matches product/unit and is allocated to this work.
  • Excavation is a vertical box only, without shoring/slope design. Swell and backfill ratio are project soil data, not code values. Backfill factor=loose/compacted volume; not an additional percentage counted twice.
  • Supply is separate from consumption; packs are whole. Excavation trips use loose volume and declared capacity; weight/road limits may increase trips. Results do not authorize construction.

Formula Summary

  • Net area = length × height × count − total openings
  • Repeating module = (unit length + joint) × (unit height + joint)
  • Paint = net area × whole coats / product coverage; plaster = net area × wet thickness
  • Earth: loose = in-situ × (1+swell); backfill loose = compacted × project ratio
  • Purchase packs = ceil(max(0, requirement − compatible stock) / pack size)

Built-in measurement definitions

QuantityIdentity
AreaL×H×N−openings
Box volumeL×W×D×N
Surplusmax(0,stock−required)+purchase−max(0,required−stock)

Declared geometric identities; no normative waste or soil factor

Results

Enter your data and press Calculate to see the results.

Engineering Insight

Diagonal patterns, cuts, irregular room geometry, large tile formats and shade-matching requirements may all require a higher waste allowance than the default.

Recommended Action

Order an attic-stock surplus from the same production batch and review the setting-out drawing before confirming the quantity.

Estimating tiles by area alone under-orders every time cuts are involved. This calculator divides the floor area by the tile area, applies the cutting-waste percentage you choose, and rounds up to whole tiles so the order matches what the site can actually lay.

Method and assumptions

Bounded geometric measurement and separate supply balance

  • Net area = length × height × count − total openings
  • Repeating module = (unit length + joint) × (unit height + joint)
  • Paint = net area × whole coats / product coverage; plaster = net area × wet thickness
  • Earth: loose = in-situ × (1+swell); backfill loose = compacted × project ratio
  • Purchase packs = ceil(max(0, requirement − compatible stock) / pack size)
  • Regular rectangular measurement only; openings cover all surfaces and cannot exceed gross area. Intermediate quantities are not rounded. RICS NRM2(2021) informs measurement boundaries, not a claim to implement every deduction rule.
  • https://www.rics.org/content/dam/ricsglobal/documents/standards/october_2021_nrm_2.pdf
  • Masonry/tiles: repeating module with joint, not a cutting layout; boundaries, bond and patterns need project take-off. No mortar, grout or strength calculation.
  • Paint uses practical product-datasheet coverage per whole coat. Plaster is wet volume only, not mix constituents. Stock matches product/unit and is allocated to this work.
  • Excavation is a vertical box only, without shoring/slope design. Swell and backfill ratio are project soil data, not code values. Backfill factor=loose/compacted volume; not an additional percentage counted twice.
  • Supply is separate from consumption; packs are whole. Excavation trips use loose volume and declared capacity; weight/road limits may increase trips. Results do not authorize construction.

Worked example

Two rooms of 5.20 m × 4.40 m tiled with 600 × 600 mm tiles and 8% cutting waste.

Worked example results
ResultValue
Gross measured area45.76 m²
Total openings across all surfaces0 m²
Net measured area45.76 m²
Repeating module area including joint0.36 m²
Unrounded theoretical consumption127.11 tiles
Loss allowance on theoretical only10.17 tiles
Requirement including loss before stock137.28 tiles
Compatible stock used0 tiles
Whole purchase packs or batches138 units
Purchased quantity, not consumption138 tiles
Calculated surplus assuming continued compatibility0.72 tiles

These figures are produced by the same calculator engine used on this page.

Frequently asked questions

Are skirting and thresholds included?
No. The result covers floor field tiles only. Skirting, thresholds, adhesive and grout are separate items.
How is rounding handled?
The tile count is always rounded up to the next whole tile after waste is applied, because part tiles cannot be ordered.
Can I use it for wall tiling?
Yes, if you enter the wall area as the surface dimensions. The arithmetic is the same; only your waste assumption may differ.

Next step and related links

Free calculators are open to everyone, and CSV export is free for everyone too. Project saving and PDF/Excel reports come with Professional, and integrated workflows with Premium.