Ventilation & HVAC Learning Kit
When to use it
When reading ventilation calculations: understand room volume and air changes, without treating this as approved design or cooling-load sizing.
ACH: how many room-air volumes are exchanged per hour, not air-conditioner capacity.
What you get after purchase
- Ventilation calculator for eight space types (office, meeting, classroom, retail, dining, hotel, exercise, library) in the ASHRAE 62.1 style.
- Outdoor air by people, area and distribution effectiveness, compared with air changes and cooling airflow to find the governing flow.
- Theoretical round and equal-area rectangular sizes, diffuser count, unit/measurement comparisons and fan energy with three charts.
- 25 inputs connect demand to unit, duct and diffuser selection and independent supply/outdoor measurements; five tables and three charts. Fan-only annual energy/cost, separate gaps and limited sensible-capacity checks, not approved coil selection.
- Bilingual Excel file: room ventilation schedule with formulas, reference outdoor air rates and a duct sizing sheet.
- Gift book: HVAC Fundamentals Book.
A fixed-number teaching example, open to everyone before purchase, so you can see how it works.
Supporting your chances of success
This kit combines precise calculations with guidance and organisation to help you work towards your goal. We help you organise inputs, understand options and assess strengths and risks, then suggest practical steps suited to its subject — such as pricing, cash flow or marketing.
Guidance supports decisions, not guaranteed success; estimates depend on the accuracy of your inputs.
Understand the kit step by step
An integrated preliminary workflow: calculate outdoor air, total-supply ACH and sensible demand, then compare unit selection, ducts, diffusers and measurement. Sensible capacity is neither total cooling load nor approved coil selection; outdoor air belongs within total supply, not added above it.
What to prepare before starting
Prepare room dimensions, type and peak occupancy, total-supply ACH, Ez, supply temperature difference and indicative sensible load. Bring catalogue performance at design conditions, selected ducts/diffusers, total pressure, overall efficiency, duty and tariff, plus independent supply and outdoor measurements.
From information to a decision
- Calculate area and volume; outdoor air=(Rp×people+Ra×area)÷Ez. Verify illustrative rates against the adopted local code; they are not a certified edition.
- ACH flow=volume×ACH÷3.6 in L/s. Sensible flow=load watts÷(1.2×1.005×temperature difference). The maximum compatible criterion governs supply; ACH here is total supply, not exhaust or outdoor ACH.
- Compare selected supply, outdoor flow and sensible capacity against demand. Verify catalogue conditions; nominal total capacity cannot replace sensible capacity.
- Recalculate selected duct velocity using clear area and integer diffuser count. The theoretical2:1 rectangle is equal-area, not equivalent-friction; throw, noise and pressure loss need separate checks.
- Calculate fan electrical input from flow, total pressure and overall efficiency, then duty hours and cost. This is a constant-duty fan-only scenario, not compressor energy.
- Record separate supply/outdoor measurements and evidence; correct negative gaps by balancing and remeasurement. Excel links40 room slots to selection, energy and commissioning; incomplete rows block decision totals.
A simple example to explain the idea
Integrated case:8×6×3m,8 people,office,Ez1,ACH6,sensible150W/m² and11°C difference. Area48,volume144; outdoor34.4L/s,ACH240L/s and sensible542.74L/s governs,with7.2kW sensible load. Select600L/s,40 outdoor,8kW sensible,400×300mm duct and five120L/s diffusers: velocity5m/s. Fan500Pa at60% overall efficiency:0.5kW;2600hours gives1300kWh and390 cost at0.3/kWh. Measured560L/s meets supply,but32L/s outdoor is2.4 short. Separate simple public example:5×4×3=60m³;6ACH=360m³/h.
These figures are illustrative, not approved prices or guaranteed forecasts; they may differ from the worked example below.
How to interpret and use the result
Three charts compare airflow criteria,demand/selection/measurement and outdoor-air occupancy sensitivity. Excel Valid means complete inputs only,not design compliance. Never enter the full cost of a shared fan once per room or energy will be duplicated.
A common mistake to avoid
No latent load,humidity,outdoor-air treatment,infiltration,life-safety exhaust,pressure balance or multizone ventilation-efficiency calculation. Summed Voz does not establish central-unit intake compliance. Only40 prepared slots; extend ranges for more. The eight-sheet review copy has not replaced customer downloads.
Reading the detailed operating plan
25 inputs connect demand to unit, duct and diffuser selection and independent supply/outdoor measurements; five tables and three charts. Fan-only annual energy/cost, separate gaps and limited sensible-capacity checks, not approved coil selection.