FreeAvailable now — free

HVAC Unit Converter

Convert common HVAC units of measurement.

Project & Input Data

Conversion type

Power: kW; flow: L/s; pressure: Pa; temperature: °C only

Embedded standards & references

  • NIST SP8112008 appendix B; specified IT/international/conventional factors

Results are engineering aids and require verification by a qualified professional before use on a real project.

Engineering Assumptions

Direct calculation — Single physical identity with declared scope

  • No system selection or ventilation/fire/health compliance. ACH is nominal room-volume turnover, not distribution, outdoor air or clearance time; duct velocity is a mean at actual clear area.
  • Tank usable volume is separate from dead volume/freeboard; no assumed refill credit or fire storage. Pump capacity is an independent comparison at the same duty head, not a curve/NPSH check; simultaneity lies between0and100%.
  • Converter input is kW, L/s, Pa or °C by mode; absolute temperature, not temperature difference; nothing below absolute zero. NIST factors have published finite precision, not all exact.
  • https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication811e2008.pdf

Formula Summary

  • ACH=Q(m³/h)/V; mean duct velocity=Q(m³/s)/clear area
  • Usable tank=daily demand×days+reserve; water=usable+dead; height=water/area+freeboard
  • Pump comparison=max(daily demand/(hours×3600),peak×simultaneity/100)
  • IT Btu/h≈0.2930711W; TR=12000ITBtu/h≈3516.8532W; conventional inH₂O=249.0889Pa; international ft³=.028316846592m³

Definitions and fixed factors

FactorValue
BtuIT/h→W0.2930711
TR→W3516.8532 (12000×0.2930711)
inH₂O→Pa249.0889
ft³→m³0.028316846592

NIST2008 published precision; TR derived from12000BtuIT/h at the same precision; not design limits

Results

Enter your data and press Calculate to see the results.

Engineering Insight

The conversion is mathematically exact with no standard rounding; use it for a quick cross-check between drawing units and manufacturer datasheets.

Recommended Action

Make sure the correct conversion type is selected before reading the result.

Convert HVAC units when reading drawings and equipment data. Choose the conversion mode and enter the value in the displayed input unit. Free to use without signing in.

Method and assumptions

Single physical identity with declared scope

  • ACH=Q(m³/h)/V; mean duct velocity=Q(m³/s)/clear area
  • Usable tank=daily demand×days+reserve; water=usable+dead; height=water/area+freeboard
  • Pump comparison=max(daily demand/(hours×3600),peak×simultaneity/100)
  • IT Btu/h≈0.2930711W; TR=12000ITBtu/h≈3516.8532W; conventional inH₂O=249.0889Pa; international ft³=.028316846592m³
  • No system selection or ventilation/fire/health compliance. ACH is nominal room-volume turnover, not distribution, outdoor air or clearance time; duct velocity is a mean at actual clear area.
  • Tank usable volume is separate from dead volume/freeboard; no assumed refill credit or fire storage. Pump capacity is an independent comparison at the same duty head, not a curve/NPSH check; simultaneity lies between0and100%.
  • Converter input is kW, L/s, Pa or °C by mode; absolute temperature, not temperature difference; nothing below absolute zero. NIST factors have published finite precision, not all exact.
  • https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication811e2008.pdf

Next step and related links

Free calculators are open to everyone, and CSV export is free for everyone too. Project saving and PDF/Excel reports come with Professional, and integrated workflows with Premium.