Pressure Calculator
Preliminary pressure calculations.
Project & Input Data
Your project criterion: enter the value from your governing code, specification or approved supplier data. No standard value is assumed.
Your project criterion: enter the value from your governing code, specification or approved supplier data. No standard value is assumed.
Your project criterion: enter the value from your governing code, specification or approved supplier data. No standard value is assumed.
Embedded standards & references
- EPA EPANET2.2(2020) SI Hazen-Williams relation; not complete NFPA
Results are engineering aids and require verification by a qualified professional before use on a real project.
Engineering Assumptions
Direct calculation — Bounded water path or density-area demand
- Three-phase voltage is line-to-line with balanced sinusoidal load and lagging displacement factor. Power input is electrical, not mechanical output. No imbalance, harmonics or motor-efficiency model. Independent S is not merged with P/PF.
- Voltage drop is approximate using operating-temperature resistance and path reactance from product data, with one-way length. No assumed temperature correction, ampacity or protection. Capacitors are Q arithmetic only, no stage/resonance selection; a target below existing PF gives zero correction, not reduced PF.
- Water pressure is one path at actual internal diameter, water1000kg/m³ and g=9.80665. Hazen-Williams is empirical for water, not all fluids. Elevation is signed. Equivalent lengths and devices must not be duplicated. Compare at the same flow/pressure; no pump or fire-network approval.
- Density×area demand does not simulate actual sprinkler overdischarge or balancing. Density/area/hose values require project evidence; defaults are examples, not rules. Comparison success is not conformity certification.
- https://www.electrical-installation.org/enwiki/Calculation_of_voltage_drop_in_steady_load_conditions
- https://www.electrical-installation.org/enwiki/How_to_calculate_the_level_of_reactive_energy_compensation
- https://www.epa.gov/water-research/epanet
Formula Summary
- hf=10.67×(L+Leq)×Q^1.852/(C^1.852×D^4.871), SI Q=m³/s,D=m
- Signed inlet=remote+ρgz/100000+friction+separate device loss; required=max(0,signed)
Built-in definitions, not code limits
| Definition | Value |
|---|---|
| g | 9.80665m/s² |
| Assumed waterρ | 1000kg/m³ |
| Hazen-Williams SI | 10.67;1.852;4.871 |
SI constants and declared engineering relations
Results
Enter your data and press Calculate to see the results.
Engineering Insight
Keep measurements and independent inputs separate from the calculated identity; results neither design equipment nor certify conformity.
Recommended Action
Document P/S, R/X or C and pipe diameter sources; check the same operating conditions before engineering review.
Estimate fire-system pressure for preliminary review. Enter remote pressure, elevation, flow, pipe diameter and length, fittings length and Hazen-Williams C. Free to use without signing in.
Method and assumptions
Bounded water path or density-area demand
- hf=10.67×(L+Leq)×Q^1.852/(C^1.852×D^4.871), SI Q=m³/s,D=m
- Signed inlet=remote+ρgz/100000+friction+separate device loss; required=max(0,signed)
- Three-phase voltage is line-to-line with balanced sinusoidal load and lagging displacement factor. Power input is electrical, not mechanical output. No imbalance, harmonics or motor-efficiency model. Independent S is not merged with P/PF.
- Voltage drop is approximate using operating-temperature resistance and path reactance from product data, with one-way length. No assumed temperature correction, ampacity or protection. Capacitors are Q arithmetic only, no stage/resonance selection; a target below existing PF gives zero correction, not reduced PF.
- Water pressure is one path at actual internal diameter, water1000kg/m³ and g=9.80665. Hazen-Williams is empirical for water, not all fluids. Elevation is signed. Equivalent lengths and devices must not be duplicated. Compare at the same flow/pressure; no pump or fire-network approval.
- Density×area demand does not simulate actual sprinkler overdischarge or balancing. Density/area/hose values require project evidence; defaults are examples, not rules. Comparison success is not conformity certification.
- https://www.electrical-installation.org/enwiki/Calculation_of_voltage_drop_in_steady_load_conditions
- https://www.electrical-installation.org/enwiki/How_to_calculate_the_level_of_reactive_energy_compensation
- https://www.epa.gov/water-research/epanet
Next step and related links
Related calculators
- Basic Flow CalculatorFire Fighting
Free calculators are open to everyone, and CSV export is free for everyone too. Project saving and PDF/Excel reports come with Professional, and integrated workflows with Premium.